Battery energy storage · 11 models · 30 kW – 10 MW

Storage sized for industry and the grid.

Two bands, one in-house BMS + EMS + PCS platform. Commercial & industrial systems from 30 kW to 2 MW, and liquid-cooled CTX containers from 2.5 MW stacking to a 10 MW / 20 MWh, 33 kV block. Share your load profile and get a sizing proposal.

Request a sizing proposal Try the sizing calculator
Model Band Power Energy Form factor Best fit
MTX-S30MTX Standard 30 C&I 30 kW Sized to runtime Commercial cabinet · 1 × 30 kW PM Small MSME · clinic Datasheet →
MTX-S60MTX Standard 60 C&I 60 kW Sized to runtime Commercial cabinet · 2 × 30 kW PM MSME factory · hotel Datasheet →
MTX-H60MTX Hybrid 50 / 60 C&I 60 kW Sized to runtime Solar-hybrid cabinet · 50 / 60 kVA Commercial rooftop solar · critical loads Datasheet →
PTX-125PTX 125 kW C&I 125 kW Sized to runtime Industrial system · 1 × 125 kW PM Multi-line factory · cold chain Datasheet →
PTX-250PTX 250 kW C&I 250 kW 257.2 kWh · ~1 h standard Industrial system · 2 × 125 kW PM Large MSME · 200-bed hospital Datasheet →
PTX-500PTX 500 kW C&I 500 kW 514.5 kWh · ~1 h standard Industrial system · 4 × 125 kW PM Process industry · fleet depot Datasheet →
PTX-1000PTX 1 MW C&I 1 MW 1,028.9 kWh · ~1 h standard Industrial system · 8 × 125 kW PM HT industrial consumer · data-centre campus Datasheet →
PTX-2000PTX 2 MW C&I 2 MW 2,057.8 kWh · ~1 h standard Industrial system · 2 × 1 MW groups Large HT consumer · industrial park Datasheet →
CTX-5000CTX 2.5 MW Utility 2.5 MW 5.06 MWh · ~2 h 20 ft container · 20 racks · 5,040 LFP cells Energy arbitrage · peak shaving Datasheet →
CTX-6600CTX 6.6 MWh Utility 1.75 MW 6.64 MWh · ~3.8 h High-density 20 ft container · 588 Ah cells Load shifting · capacity firming Datasheet →
CTX-B20CTX Block 10 MW Utility 10 MW 20.26 MWh · ~2 h 4 × CTX-5000 · 33 kV energy block Utility & DISCOM storage · IPP solar/wind firming Datasheet →
Band 02 · Utility-scale

2 MW – 10 MW.
CTX containers & blocks.

CTX 20 ft liquid-cooled containers at 2.5 MW / 5.06 MWh, stacked into a 10 MW / 20 MWh, 33 kV energy block — and onward to 1 GWh-class plants.

2.5 MW1 × CTX-5000 · 5.06 MWh
5 MW2 × CTX-5000 · 10.1 MWh
7.5 MW3 × CTX-5000 · 15.2 MWh
10 MWCTX-B20 block · 20.26 MWh · 33 kV

Each container carries its own 2.5 MW PCS skid and 2.75 MVA 0.4/33 kV unit transformer. Blocks repeat on a 33 kV collection system up to the 500 MW / 1.01 GWh CTX plant configuration. Multi-container energy is nameplate; usable energy depends on DoD and losses.

Planning a multi-MW project?

We engineer BESS + solar hybrids, EV-charging buffers, 33 kV grid connections and multi-site fleets — with BMS, EMS, PCS and PDMS from one in-house team.

Talk to an engineer