Commercial & Industrial · 30 kW – 2 MW

MTX-H60MTX Hybrid 50 / 60 · 60 kW

Solar-hybrid cabinet · 50 / 60 kVA · Commercial rooftop solar · critical loads · 3-phase unbalanced sites

Solar + storage + backup in one cabinet. The MTX Hybrid integrates two MPPTs (38.4 kW each) and a built-in switching device for grid ↔ off-grid transfer in under 10 ms, with 100% unbalanced-load support on a 400/230 V four-wire output.

TOBOR MTX-H60 — Solar-hybrid cabinet · 50 / 60 kVAMTX series · representative image
Power
50 / 60 kVA
Transfer
< 10 ms
Solar
2 × 38.4 kW MPPT
PM efficiency
97.8%
Specification · MTX-H60

Full technical sheet.

AC & battery

  • Rated / peak output50 / 60 kVA · peak 55 / 66 kVA
  • Active power50 / 60 kW at unity PF
  • Rated AC current73 A / 87 A
  • AC output400 / 230 V · 3-phase 4-wire
  • Grid voltage range-20% → +20%
  • Battery window350–820 V (50 kVA) · 420–820 V (60 kVA)
  • Max battery current150 A
  • Mode transfer< 10 ms (PM specification)
  • Unbalanced load100%

Solar integration

  • PV inputs2 MPPTs · 38.4 + 38.4 kW
  • MPPT window200–800 V
  • PV start / max voltage250 V / 850 V
  • Max PV current64 A + 64 A
  • Off-grid parallelUp to 15 PMs

Environment

  • Operating temp-30 °C → +60 °C (derates above 45 °C)
  • PM coolingForced air · IP20 PM inside cabinet
  • Battery chemistryLiFePO4 · 3.2 V 100 Ah · ~6,000 cycles*
  • CommunicationEMS RS485 · battery CAN / RS485

Control & monitoring

  • Battery managementIn-house TOBOR BMS
  • Energy managementIn-house TOBOR EMS
  • Dispatch modesPeak shaving · ToU shifting · Solar self-use · Backup reserve
  • Site integrationGrid · Solar PV · DG · EV charging
  • Remote accessCloud EMS dashboard · remote diagnostics

Catalogue values. *Cycle capability depends on depth of discharge, C-rate, temperature and end-of-life criterion. Peak PM efficiency is not whole-system round-trip efficiency. Usable energy and runtime depend on permitted DoD, conversion losses and auxiliaries. Final ratings and compliance follow the approved project-specific offer.

Compatible applications

Where this size fits.

Peak-demand shaving

Clip maximum-demand peaks with EMS dispatch inside battery limits. Demand-charge savings are sized from your 15-minute interval data.

Solar self-consumption

Charge from surplus rooftop or ground-mount PV and dispatch it into evening and night shifts instead of exporting at low rates.

DG-hours reduction

Carry critical loads through outages and cut generator runtime. Battery capacity is sized to the outage profile and priority loads.

BESS-buffered EV charging

Run TOBOR DC fast chargers on a smaller grid connection — the battery covers the charging peaks, the EMS coordinates both.

Ready to size your project?

Share your interval load data, tariff and grid limits. Our engineers return a kW / kWh sizing, dispatch logic and a techno-commercial offer.

Request quote

Questions and answers

What is the MTX-H60?
Solar + storage + backup in one cabinet. The MTX Hybrid integrates two MPPTs (38.4 kW each) and a built-in switching device for grid ↔ off-grid transfer in under 10 ms, with 100% unbalanced-load support on a 400/230 V four-wire output.
What loads does the MTX-H60 support?
Sized for Commercial rooftop solar · critical loads · 3-phase unbalanced sites. Rated output 60 kW, with LFP battery capacity sized to the required runtime. Peak-demand shaving, solar self-consumption, DG-hours reduction and BESS-buffered EV charging.
Where is the MTX-H60 manufactured?
Designed and manufactured at the TOBOR facility in Gurugram, Haryana, India. BMS, EMS, power conversion and firmware are engineered in-house; LFP cells are integrated into TOBOR-engineered packs and racks.