Commercial & Industrial · 30 kW – 2 MW
MTX-S30MTX Standard 30 · 30 kW
Commercial cabinet · 1 × 30 kW PM · Small MSME · clinic · retail · 30 kVA DG replacement
Entry point to TOBOR commercial storage: one 30 kW bidirectional, isolated power module in the two-bay MTX cabinet. Built for peak management and load shifting at small factories, clinics, restaurants and offices, with automatic battery restart for loads that tolerate a short interruption.
Full technical sheet.
Power conversion
- Configured power30 kW · 1 PM
- Power module30 kW bidirectional, high-frequency isolated
- AC voltage range260–530 V · 3-phase + PE
- DC range150–1000 V (full power 300–1000 V)
- Peak PM efficiency≥ 95.5%
- Charging power factor≥ 0.99
- Backup transferAutomatic restart in ~30–40 s
- Parallel supportUp to 8 PMs off-grid · 60 PMs grid-tied
Battery
- Cell chemistryLiFePO4 (LFP)
- Cell platform3.2 V · 100 Ah
- Stored energySized to required backup duration
- Cycle capability~6,000 cycles*
Cabinet & environment
- ConstructionTwo-bay cabinet · battery bay + equipment bay
- Footprint (50 kW ref.)1,654 × 1,000 × 1,856 mm
- CoolingForced air
- Operating temp-40 °C → +70 °C (full rating to +55 °C)
- PM communicationCAN
Control & monitoring
- Battery managementIn-house TOBOR BMS
- Energy managementIn-house TOBOR EMS
- Dispatch modesPeak shaving · ToU shifting · Solar self-use · Backup reserve
- Site integrationGrid · Solar PV · DG · EV charging
- Remote accessCloud EMS dashboard · remote diagnostics
Catalogue values. *Cycle capability depends on depth of discharge, C-rate, temperature and end-of-life criterion. Peak PM efficiency is not whole-system round-trip efficiency. Usable energy and runtime depend on permitted DoD, conversion losses and auxiliaries. Final ratings and compliance follow the approved project-specific offer.
Where this size fits.
Peak-demand shaving
Clip maximum-demand peaks with EMS dispatch inside battery limits. Demand-charge savings are sized from your 15-minute interval data.
Solar self-consumption
Charge from surplus rooftop or ground-mount PV and dispatch it into evening and night shifts instead of exporting at low rates.
DG-hours reduction
Carry critical loads through outages and cut generator runtime. Battery capacity is sized to the outage profile and priority loads.
BESS-buffered EV charging
Run TOBOR DC fast chargers on a smaller grid connection — the battery covers the charging peaks, the EMS coordinates both.
Other commercial & industrial models.
MSME factory · hotel · hospital wing · 60 kVA DG replacement
Commercial rooftop solar · critical loads · 3-phase unbalanced sites
Multi-line factory · cold chain · commercial complex · EV-charging buffer
Large MSME · 200-bed hospital · IT campus · 250 kVA DG replacement
Process industry · fleet depot · commercial campus · 500 kVA DG replacement
HT industrial consumer · data-centre campus · C&I solar park
Large HT consumer · industrial park · open-access solar · DCFC hub
Ready to size your project?
Share your interval load data, tariff and grid limits. Our engineers return a kW / kWh sizing, dispatch logic and a techno-commercial offer.
Request quote